Realigning a QD Rotor
If your rotor is no longer stopping in the upright position (12:00), it may be misaligned with the cam or encoder wheel. In this step-by-step guide, weโll walk you through the realignment procedure for a Quick Disconnect (QD) Rotor on a SITEK/Semitool 8300 Spin Rinse Dryer, ensuring your Rotor Stop Positioner (RSP) functions properly.
Prefer watching instead?
Check out our full video guide below for a step-by-step demonstration:
โ ๏ธ Note:
The Nitrogen (Nโ) supply and controller must be active during this process so the RSP can engage.
Step-by-Step Instructions
1. Remove the Rotor Bolt
- Remove the center rotor bolt completely using a T-handle or Allen wrench.
2. Check Rotor Pin Alignment
- Place the rotor back onto the motor shaft.
- Rotate it until it “clicks” into the notch.
- When aligned, you should feel it securely seat and self-center.
3. Access the Rear Cam Assembly
- Go to the back of the Spin Rinse Dryer.
- Loosen both set screws on the cam.
- If necessary, loosen the Nylock nut on the QD shaft using a crescent wrenchโjust enough to allow rotation.
4. Set the Rotor to the 12:00 Position
- Have someone hold the rotor from the front at the 12:00 position.
- Ensure it’s still engaged in the notch and doesnโt shift.
5. Align the Encoder Wheel
- Rotate the encoder wheel until the notch is centered in the RSP optical sensor.
- Make sure itโs perfectly alignedโif misaligned, the rotor-up error will persist.
6. Tighten the Cam Hardware
- While keeping the rotor locked at 12:00, tighten:
- The set screws on the cam and encoder wheel.
- The Nylock nut on the QD shaft.
7. Reinstall the Rotor Bolt
- Once alignment is confirmed, reinstall the QD rotor bolt and snug it securely.
8. Test Alignment
- Spin the rotor slightly and let goโit should return to 12:00 automatically.
- If not, repeat the process and ensure all hardware is firmly tightened.
Troubleshooting:
No response from the sensor? The RSP sensor may be faulty and require replacement.
Still getting a Rotor Up error? The encoder wheel may still be slightly misaligned with the sensor.
Need help servicing your SRD?
๐ +1 916-797-9000
โ๏ธ sales@sitekprocess.com
We repair and support Semitool, Verteq, and SITEK Spin Rinse Dryers, and we carry all the spare parts you need.
For more tutorials and maintenance tips, follow us on YouTube:
www.youtube.com/@sitekprocesssolutions3279