June 26, 2025

How to Realign a Quick-Disconnect Rotor on a SITEK / Semitool Spin Rinse Dryer

If your Spin Rinse Dryer rotor isnโ€™t stopping at 12:00, this guide walks you through aligning the cam, encoder wheel, and RSP sensor on a SITEK/Semitool 8300 SRD. Learn how to lock the rotor in place, verify notch alignment, and tighten all key hardware. Watch the full video to see the process in action.

If your rotor is no longer stopping in the upright position (12:00), it may be misaligned with the cam or encoder wheel. In this step-by-step guide, weโ€™ll walk you through the realignment procedure for a Quick Disconnect (QD) Rotor on a SITEK/Semitool 8300 Spin Rinse Dryer, ensuring your Rotor Stop Positioner (RSP) functions properly.

โš ๏ธ Note:

The Nitrogen (Nโ‚‚) supply and controller must be active during this process so the RSP can engage.

Step-by-Step Instructions

1. Remove the Rotor Bolt

  • Remove the center rotor bolt completely using a T-handle or Allen wrench.

2. Check Rotor Pin Alignment

  • Place the rotor back onto the motor shaft.
  • Rotate it until it “clicks” into the notch.
  • When aligned, you should feel it securely seat and self-center.

3. Access the Rear Cam Assembly

  • Go to the back of the Spin Rinse Dryer.
  • Loosen both set screws on the cam.
  • If necessary, loosen the Nylock nut on the QD shaft using a crescent wrenchโ€”just enough to allow rotation.

4. Set the Rotor to the 12:00 Position

  • Have someone hold the rotor from the front at the 12:00 position.
  • Ensure it’s still engaged in the notch and doesnโ€™t shift.

5. Align the Encoder Wheel

  • Rotate the encoder wheel until the notch is centered in the RSP optical sensor.
  • Make sure itโ€™s perfectly alignedโ€”if misaligned, the rotor-up error will persist.

6. Tighten the Cam Hardware

  • While keeping the rotor locked at 12:00, tighten:
    • The set screws on the cam and encoder wheel.
    • The Nylock nut on the QD shaft.

7. Reinstall the Rotor Bolt

  • Once alignment is confirmed, reinstall the QD rotor bolt and snug it securely.

8. Test Alignment

  • Spin the rotor slightly and let goโ€”it should return to 12:00 automatically.
  • If not, repeat the process and ensure all hardware is firmly tightened.

Troubleshooting:

No response from the sensor? The RSP sensor may be faulty and require replacement.

Still getting a Rotor Up error? The encoder wheel may still be slightly misaligned with the sensor.

๐Ÿ“ž +1 916-797-9000
โœ‰๏ธ sales@sitekprocess.com

We repair and support Semitool, Verteq, and SITEK Spin Rinse Dryers, and we carry all the spare parts you need.

For more tutorials and maintenance tips, follow us on YouTube:
www.youtube.com/@sitekprocesssolutions3279